Installation
Connect a Class 2 power supply with 12-24 VDC output voltage to the input connector of casDMX. Make sure not to use a constant current LED driver and make sure that the cable polarity is correct.
The product has one DMX universe, with a DMX+ and DMX– connection, plus a ground. Connect the DMX load wires accordingly.
CasDMX can be configured having different types of outputs, such as 4 channel RGBW (color picker), 4 individual channels, and 8 individual channels. DMX addresses start at slot or address 1, and are sequential. These configurations can be made by the end-user from Casambi App using Pro-files. As default, casDMX is delivered with RGBW configuration.
casDMX should not be placed in a metal enclosure, such as metal junction boxes. Metal will attenuate radio signals which are crucial to the operation of the product. If the product will have to install into a junction box, make sure to use a plastic junction box.
casDMX is an ETL Listed Open-Type device which means that it will have to be used together with a Class 2 power supply with a maximum output power of 100 VA. The product can be installed outside of the junction box. Make sure to comply with National Electric Code in installation and when selecting installation wires.